Contact Us: Call (813) 616-3661 or Email sales@dwixt.com

  • Fast Reliable Shipping

  • Special Offers & Discounts

  • Price Match Guarantee

  • Chat with Customer Service

Dwixt

Pallet Rack Flue Guards – Longitudinal Flue Space Control

Regular priceFrom $8.95
Shipping calculated at checkout.

Type
Customer Service
Questions? We're here to help!

Price Match Guarantee

Get More for Less with Dwixt - Save Up to 5% on Your Purchase!

At Dwixt, we don't just offer products; we ensure you get them at the best possible prices. If you come across a lower price on another online store, let us know!

Simply send us an email at sales@dwixt.com with a link to the competitor's product. We'll respond with a personalized quote, offering you a deal that's not just a match, but up to 5% less.

Your trust in our pricing is paramount. That's why our 100% Price Match Guarantee is designed to give you peace of mind.

However, please note that our guarantee is subject to a few reasonable conditions:

  • Excludes promotions like rebates, and buy one, get one free offers.
  • Applies only to items currently in stock.
  • Valid for prices on non-discount or auction websites (such as eBay, Overstock, etc.).
  • The competitor must be an authorized retailer of the product.
  • The price comparison will include the total cost - encompassing the item's price, sales tax, and shipping charges.
  • Please note that our Price Match Guarantee does not apply to exchange orders.

Choose Dwixt for not only great products but also the assurance of getting the best deal out there!

Request A Quote

How to Send a Quote Request to Dwixt

If you're interested in receiving a quote from Dwixt, kindly follow the instructions below to ensure a smooth and prompt response:

1. Starting Your Email:
Address your email to our official quote request email address sales@dwixt.com.

2. Setting the Subject Line:
Be sure to use "Quote Request" in the subject line of your email. This helps us quickly identify and prioritize your request.

3. Providing Essential Information:
Ship To Address: Clearly mention the address where you would like the product(s) to be delivered.

Bill To Address: If the billing address is different from the shipping address, please include this as well. This ensures there's no confusion during the billing process.

Part Number: Specify the part number(s) of the product(s) you're interested in. This helps us to identify the exact product you need.

Quantity: Mention the number of units of each part you wish to order. This assists in providing a comprehensive quote.

4. Additional Information:
While the above details are crucial for your quote, consider adding any other relevant information or questions you may have about the product or the shipping process.

5. Sending the Email:
Once you've ensured all necessary details are included, click the 'Send' button to forward your quote request to us.

6. Await Our Response:
Our team at dwixt will review your request and respond with a detailed quote, typically within the same business day or next day.

Thank you for considering Dwixt for your needs. We look forward to assisting you!

Shipping Quotations

  1. Add Products: Select your desired items and add them to your cart.
  2. Checkout: Proceed to the checkout page.
  3. Enter Address: Input your shipping address to receive an accurate quote.
  4. View Quote: The shipping cost will be displayed before any payment is requested.
  5. Decide: If you're satisfied, continue to payment. If not, adjust your cart or contact us.

We prioritize transparency. See your full costs upfront and shop with confidence.

Pallet rack flue guards – beam-mounted flue space control for NFPA 13 compliance

Keep the flue open so the sprinklers can do their job. These flue guards bolt to the rear beam of a pallet rack and stop pallets from being pushed back into the longitudinal flue space between back-to-back rows. A fixed, visible flue lets overhead sprinklers reach the floor in a fire, which is what NFPA 13 and the International Building Code ask for, and a documented flue can help at insurance renewal. Four models cover a 3 in. single stop through an 18 in. double stop, all with pre-punched holes and self-drilling screws included.

Also called: flue space guards, flue guards, rack flue space dividers, pallet stops for racking, pallet rack backstops, flue space keepers, longitudinal flue dividers. If you have been searching under any of those names, this is the product.

How it works

  • Controls pallet placement so a load cannot be pushed through into the flue behind the rack
  • Meets NFPA 13 and IBC 2012 flue space requirements when installed on both rows of a back-to-back run
  • Rigid box section, robotically welded for strength without adding weight to the beam
  • Installs in minutes with four pre-punched, countersunk holes; self-drilling screws are in the box
  • Clears wire decking with an integral offset rib and a slot that fits over decking wire up to 2 gauge
  • Grey powder coat finish

Single stop or double stop

A single stop mounts on one beam and holds the pallet 3 in. off the beam face. Use it where only one side of the flue needs a stop, or where the two rows are set at different heights. A double stop straddles the flue and holds both rows at once, fixing the gap at 6 in. or 12 in. depending on the model. The heavy duty single stop uses thicker steel for racks that see hard forklift use.

Model Type Flue created Weight
FG-SS-3 Single stop 3 in. offset from the beam 2.4 lb
FG-SS-HD Single stop, heavy duty 3 in. offset from the beam 1.3 lb
FG-DS-12 Double stop, 12 in. 6 in. flue between rows 4.1 lb
FG-DS-18 Double stop, 18 in. 12 in. flue between rows 5.7 lb

How many do you need

Plan on two per pallet position per level, one near each end of the pallet, so the load cannot pivot past a single stop. A 96 in. bay holding two pallets takes four. For a full aisle, count pallet positions times levels times two. Ships from stock; larger runs ship on a pallet by freight.

Fitting out the racking? See our pallet rack wire decking, U-dividers for transverse flue space and the full rack accessories range.

Frequently asked questions

What is longitudinal flue space and why does it matter?

It is the gap between the backs of two pallet rack rows placed back to back. Fire codes require it to stay open so sprinkler water can reach the lower levels and the floor. Pallets pushed too far back close the gap, and flue guards stop that from happening.

Single stop or double stop?

A double stop sets the flue between both rows in one piece and is the usual choice for back-to-back racking at matching heights. A single stop suits a single row against a wall, rows at different beam heights, or where you only need to hold one side.

Do they work with wire decking?

Yes. The offset rib lifts the guard clear of the deck and the slot fits over decking wire up to 2 gauge, so they mount over standard wire decks without modification.

What do I need to install them?

A drill and the self-drilling screws that come in the box. The four holes are pre-punched and countersunk, so each guard goes on in a minute or two.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Fire Code Compliant Flue Space Control for Pallet Rack

Maintain proper longitudinal flue space between back-to-back pallet rack rows with these beam-mounted flue guards. Designed to meet NFPA 13 and IBC 2012 fire code requirements, they create a fixed flue space that allows overhead sprinklers to penetrate effectively in the event of a fire. Proper flue space control may also qualify your facility for reduced insurance premiums.

Key Features

  • Pallet rack flue guard, flue space control, Pallet Flue Patented design – Dwixt, image 6 of 7

    Patented design controls pallet placement and prevents push-through
    Durable gray powder coat finish

  • Meets International Building Code 2012 (IBC 2012) and NFPA 13 requirements

  • Pallet rack flue guard, flue space control, 4 pre punched 2 – Dwixt, image 5 of 7

    Installs easily with 4 pre-punched, countersunk holes — Tek screws included

  • Rigid box design, robotically welded for superior strength
     

  • Pallet rack flue guard, flue space control, Pallet Rack Flue 2 gauge wire diameter – Dwixt, image 7 of 7

    Clearance slot fits over wire deck applications up to 2-gauge wire diameter
    Integral offset rib for wire deck clearance

Single Stop vs. Double Stop

  • Single Stop: For single-row rack configurations (e.g., wall-side rows). Creates a 3 in. offset preventing pallets from overhanging into the flue space.
  • Double Stop: For back-to-back rack configurations. Sits between two rows and creates a fixed 6 in. or 12 in. flue space with stops on both sides.

Available Styles

  • Single Stop

    a. Top of beam dimension (stock fits 1.75")
    b. Face of beam dimension
    c. Step dimension (for step beams)
    d. Offset (standard 3")

  • Double Stop

    a. Inside clear / rack flue space (measured face of beam to face of beam)
    b. Outside clear (includes top of beams)
    c. Top of beam dimension (stock fits 1.75")
    d.
    Step dimension
    e.
    Offset (standard 3")
    f. Actual flue space to maintain (the "flue within the flue" - e.g., for a 12" rack flue space, F = 6")

Pallet rack flue guard, flue space control, Pallet Flue Patented design – Dwixt, image 6 of 7

Additional Details

  • Stock products fit 1.75" top of beam
  • Standard offset is 3" on both single and double stops
  • Compatible beam types: step beam, box beam, or structural beam
  • Standard finish: powder coat gray
  • Custom orders and large quantity orders require a completed spec sheet from the customer

Request a Quote